AHU Systems — Evaporative & Hybrid Cooling

Air Handling Units built to run on 100% fresh air, not recirculated room air — from Degree Day’s D-Series and DX-Series ranges. Below: what each one does, real specs, and — at the end — a straight answer on which fits hospitals, hotels & banquets, and schools.

Not sure which AHU fits your space?

We run a free site survey and recommend D-Series, DX-Series, or a mixed layout — based on your building, footfall and season.

Book a free survey
Degree Day · D-Series

Dual-Stage Evaporative Cooling AHU

A high-performance double-skin AHU combining indirect and direct evaporative cooling. It draws 100% fresh outdoor air, cools it in two stages, and supplies it without adding refrigerant, compressors or recirculated air — an eco-friendly, low-running-cost alternative to conventional AC for dry and moderate climates.

Degree Day D-Series dual-stage evaporative cooling AHU unit
1

Fresh outdoor air in

~42–44°C
2

Sensible Heat Rejection coil (indirect stage)

30–32°C
3

Cellulose evaporative pad (direct stage)

18–20°C
4

Supply to conditioned space

22–24°C room, 55–65% RH
Airflow range1,000 – 40,000 CFM modular units · up to 200,000 CFM for built-up structures
Supply air temperatureAs low as 18°C, room temperature 22–24°C at 55–65% RH in peak summer
Power consumptionAs low as ~20% of a conventional AC system
Static pressure250 to 1,500 Pascals, selectable
Filtration20 micron to 0.3 micron options
Where it needs pairing: D-Series is built for dry and moderate climates. During Gorakhpur’s hot, humid monsoon spells, comfort settles around 28–30°C rather than tight AC-level control — for spaces that must hold comfort year-round, pair it with DX-Series or a spot AC.
Enquire about D-Series
Degree Day · DX-Series

Hybrid Evaporative + AC Cooling AHU

The DX-Series is Degree Day’s upgrade over the D-Series for mid-to-large spaces — a hybrid AHU that intelligently switches between evaporative cooling and full air-conditioning, sensing wet-bulb and room temperature, so one machine gives you year-round comfort instead of two separate systems.

Degree Day DX-Series hybrid AHU with outdoor AC condenser and cooling tower
Dry season

Evaporative cooling mode

Fresh-air circulation at the lowest possible running cost — the same low-power stage as D-Series, used whenever outdoor wet-bulb conditions allow it.

Senses wet-bulb &
room temperature
Humid / monsoon

Air-conditioning mode

Switches over automatically in hot, humid conditions to deliver temperature-controlled comfort — can integrate with an existing chilled-water plant to cut costs further.

Enquire about DX-Series
Side by side

D-Series vs DX-Series

D-SeriesDX-Series
Cooling methodTwo-stage evaporative only (indirect + direct)Hybrid — evaporative + full AC, auto-switching
Best climate fitDry & moderate climates, peak Apr–Jun heatYear-round, including humid monsoon spells
Running costLowest — as low as ~20% of conventional ACLow on average — AC mode used only when needed
Comfort in humid weatherComfort settles ~28–30°CFull AC-level comfort maintained
Typical use hereSchools, back-of-house, dry-season crowd coolingHospital OPDs, hotel & banquet guest areas
Which series for your building

Hospitals, hotels & banquets, and schools

Hospitals

DX-Series for OPD & waiting areas, D-Series for back-of-house

Best fit: DX-Series for OPD halls, corridors and visitor waiting areas — it holds comfort through Gorakhpur’s humid monsoon spells, when a stand-alone evaporative unit would drift to 28–30°C.

D-Series works well for stores, laundry, staff and back-of-house zones, and is unbeatable on running cost through the dry, pre-monsoon heat of April–June.

OT, ICU and isolation areas still need dedicated medical-grade AC — these AHUs are for common and support areas, not critical care.

Hotels & Banquets

Both series clear food & crowd smell; DX-Series holds guest comfort

Either series solves the kitchen-and-crowd smell problem — 100% fresh air with no recirculation clears cooking odour from restaurants and banquet halls far better than recirculating split ACs.

DX-Series is the safer pick for guest-facing halls that must hold comfort through humid banquet season (Sept–Nov weddings); D-Series is the low-cost choice for the dry-season crowd.

Schools

D-Series is the natural fit for classrooms

D-Series suits classrooms and corridors well — lowest running cost (as low as ~20% of conventional AC), 100% fresh filtered air for growing lungs, and near-zero maintenance for institutional budgets.

Where the budget allows, DX-Series extends full comfort through the humid months too — useful for exam halls and admin blocks used year-round.

Specifications summarised from Degree Day’s published D-Series and DX-Series literature. Final unit sizing, static pressure and layout are engineered to your site after a free survey.